E l e c a l P o w e r ( E L 7 5 0 0 S ) | |
Rated Output: 4.5~ 5.5 KVA | |
Prime Power 50Hz: N/A |
General Features:
Strong power, used 4 stroke engine, low noise, optimization structure design, reduce engine itself make noise, double muffler structure effectively lower the noise, intelligent control panel – user can know the details on the panel.
E l e c a l P o w e r ( E L 1 2 S S ) | |
Rated Output: 10~12 KVA | |
Prime Power 50Hz: N/A |
General Features:
Strong power, used 4 stroke engine, low noise, optimization structure design, reduce engine itself make noise, double muffler structure effectively lower the noise, intelligent control panel – user can know the details on the panel.
E l e c a l P o w e r ( E L 1 9 S S ) | |
Rated Output: 15~17 KVA | |
Prime Power 50Hz: N/A |
General Features:
Strong power, used 4 stroke engine, low noise, optimization structure design, reduce engine itself make noise, double muffler structure effectively lower the noise, intelligent control panel – user can know the details on the panel.
E l e c a l P o w e r ( E L 2 5 S S ) | |
Rated Output: 20~25 KVA | |
Prime Power 50Hz: N/A |
General Features:
Strong power, used 4 stroke engine, low noise, optimization structure design, reduce engine itself make noise, double muffler structure effectively lower the noise, intelligent control panel – user can know the details on the panel.
MODEL: BF-C28 | |
Standby Power 50Hz: | 22KW / 28KVA |
Prime Power 50Hz: | 20KW / 25KVA |
General Features:
Engine DCEC Cummins 4B3.9-G1, Radiator 50 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C40 | |
Standby Power 50Hz: | 33KW / 41KVA |
Prime Power 50Hz: | 30KW / 38KVA |
General Features:
Engine DCEC Cummins 4B3.9-G1, Radiator 50 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C65 | |
Standby Power 50Hz: | 52KW / 65KVA |
Prime Power 50Hz: | 48KW / 60KVA |
General Features:
Engine DCEC Cummins 4B3.9-G1, Radiator 50 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C103 | |
Standby Power 50Hz: | 82KW / 102KVA |
Prime Power 50Hz: | 74KW / 93KVA |
General Features:
Engine DCEC Cummins 4B3.9-G1, Radiator 50 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C110 | |
Standby Power 50Hz: | 87KW / 109KVA |
Prime Power 50Hz: | 80KW / 100KVA |
General Features:
Engine DCEC Cummins 6BT5.9-G2, Radiator 50 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C125 | |
Standby Power 50Hz: | 100KW / 125KVA |
Prime Power 50Hz: | 92KW / 115KVA |
General Features:
Engine DCEC Cummins 6BTA5-G2, Radiator 50 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C175 | |
Standby Power 50Hz: | 140KW / 175KVA |
Prime Power 50Hz: | 128KW / 160KVA |
General Features:
Engine DCEC Cummins 6CTA8.3-G2, Radiator 50 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C200 | |
Standby Power 50Hz: | 160KW / 200KVA |
Prime Power 50Hz: | 145KW / 181KVA |
General Features:
Engine DCEC Cummins 6CTA8.3-G2, Radiator 50 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C220 | |
Standby Power 50Hz: | 176KW / 220KVA |
Prime Power 50Hz: | 160KW / 200KVA |
General Features:
Engine DCEC Cummins 6CTA8.3-G2, Radiator 50 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C275 | |
Standby Power 50Hz: | 220KW / 275KVA |
Prime Power 50Hz: | 200KW / 220KVA |
General Features:
Engine DCEC Cummins 6LTAA8.9-G2, Radiator 50 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C350 | |
Standby Power 50Hz: | 260KW / 325KVA |
Prime Power 50Hz: | 240KW / 300KVA |
General Features:
Engine DCEC Cummins Cummins MTAA11-G3, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C360 | |
Standby Power 50Hz: | 280KW/350KVA |
Prime Power 50Hz: | 240KW / 300KVA |
General Features:
Engine DCEC Cummins NTA855-G1B, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C375 | |
Standby Power 50Hz: | 300KW / 375KVA |
Prime Power 50Hz: | 275KW / 344KVA |
General Features:
Engine DCEC Cummins NTA855-G2A, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C412 | |
Standby Power 50Hz: | 330KW / 412KVA |
Prime Power 50Hz: | 300KW / 375KVA |
General Features:
Engine CCEC Cummins NTAA855-G7, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C500 | |
Standby Power 50Hz: | 400KW / 500KVA |
Prime Power 50Hz: | 360KW / 450KVA |
General Features:
Engine CCEC Cummins KTA19-G3, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C550 | |
Standby Power 50Hz: | 440KW / 550KVA |
Prime Power 50Hz: | 400KW / 500KVA |
General Features:
Engine CCEC Cummins KTA19-G4, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C625 | |
Standby Power 50Hz: | 500KW / 625KVA |
Prime Power 50Hz: | NA |
General Features:
Engine CCEC Cummins KTAA19-G5, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C688 | |
Standby Power 50Hz: | 550KW / 688KVA |
Prime Power 50Hz: | NA |
General Features:
Engine CCEC Cummins KTAA19-G6A, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C825 | |
Standby Power 50Hz: | 660KW / 825KVA |
Prime Power 50Hz: | 600KW / 750KVA |
General Features:
Engine CCEC Cummins KTA38-G2, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C880 | |
Standby Power 50Hz: | 704KW / 880KVA |
Prime Power 50Hz: | 640KW / 800KVA |
General Features:
Engine CCEC Cummins KTA38-G2A, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C1000 | |
Standby Power 50Hz: | 800KW / 1000KVA |
Prime Power 50Hz: | 728KW / 910KVA |
General Features:
Engine CCEC Cummins KTA38-G2A, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C1100 | |
Standby Power 50Hz: | 880KW / 1100KVA |
Prime Power 50Hz: | 800KW / 1000KVA |
General Features:
Engine CCEC Cummins KTA38-G5, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Main line circuit breaker, Permanent Magnet Generator (PMG), Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C1250 | |
Standby Power 50Hz: | 1000KW / 1250KVA |
Prime Power 50Hz: | N/A |
General Features:
Engine CCEC Cummins KTA38-G9, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Main line circuit breaker, Permanent Magnet Generator (PMG), Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C1375 | |
Standby Power 50Hz: | 1100KW / 1375KVA |
Prime Power 50Hz: | 1000KW / 1250KVA |
General Features:
Engine CCEC Cummins KTA50-G3, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Main line circuit breaker, Permanent Magnet Generator (PMG), Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.
MODEL BF-C1600 | |
Standby Power 50Hz: | 1300KW / 1625KVA |
Prime Power 50Hz: | 1100KW / 1375KVA |
General Features:
Engine CCEC Cummins KTA50-G8, Radiator 40 Celsius max, fans are driven by belt, with safety guard, 24V charge alternator, single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter, Main line circuit breaker, Main line circuit breaker, Permanent Magnet Generator (PMG), Standard control panel, two 12V batteries, rack and cable,ripple flex exhaust pipe, exhaust siphon, flange, muffler.